Product Description
Scope of application:
Ultraviolet sterilization furnace can be used to sterilize air and objects. Widely used in hospitals, food, tea, beverage processing and packaging equipment, food factory, cosmetics factory, milk factory, brewery, beverage factory, bakery and cold room, etc. And can extend the product shelf life and other standards.
How it works:
The ultraviolet sterilization band is mainly between 200-300mm, of which 253.7mm wavelength sterilization ability is the strongest. When various bacterial viruses in water or air pass through the area irradiated by ultraviolet light (253.7m wavelength), the ultraviolet light penetrates the cell membrane and nucleus of the microorganism, destroys the nucleic acid (DNA or RNA) molecular bonds, so that it loses its replication ability or loses its activity and dies, thus killing all bacterial viruses without the use of any chemical drugs. Germicidal lamps do not need to be converted into visible light, 100-200nm wavelength can play a very good bactericidal effect, this is because the cell's absorption of light waves has a law in the 100-200nm ultraviolet rays have the greatest absorption, the absorbed ultraviolet rays actually act on the cell's genetic material that DNA it plays a photochemical role, The energy of ultraviolet photons is absorbed by the base pairs in the DNA, causing genetic material to mutate so that the bacteria immediately die or cannot reproduce offspring, achieving the purpose of sterilization.
Main structure of equipment:
1, the outer body of the working area tunnel: a set of advanced brushed stainless steel
2, working area tunnel cavity: mirror stainless steel plate set
3, body support frame: square steel set
4, air system: a set of forced air combined extraction fan
5, heat insulation material: vacuum aluminum silicate + silk cotton double layer
6, conveyor belt: Tiephron mesh belt
7, balancing device: flat foot cup
Product parameters:
Full length of equipment: |
2000mm |
UV working area: |
1200mm |
Feeding operation area: |
400mm |
Discharge operation area: |
400mm |
Height of entrance and exit: |
200mm (adjustable) |
Width of inlet and outlet: |
500mm |
Conveyor belt distance from ground: |
750±50mm |