Product Manual:
Computer-controlled high-precision full-automatic plug-in force testing machine, which is mainly used to detect the plug-in force, pull-out force, retention force, breaking force and other parameters of various connectors, shells, terminals, etc., through computer data analysis, can be accurately detected The load, stroke and the corresponding change curve, life curve, etc. of the connector are summarized through the data report. So as to provide various scientific data for product quality testing. This instrument uses an automatic heart-seeking device to solve the problems of male and female misalignment and unilateralism when testing various connectors. It is suitable for testing various products with different specifications.
Product use/standard
This machine is used to test the insertion force and pull-out force of various connectors. With a dedicated automatic heart-seeking device, it will be able to obtain completely accurate insertion and pull-out force tests, inspection reports, etc. The automatic center finding device is adopted to solve the fixture problems of various connection tests, and the male and female connectors can be automatically aligned during the test, and there will be no single-sided problems.
Determine the maximum load range |
2, 5, 20, 50kg |
Control method |
Computer control |
Test speed |
0-200mm/min |
Maximum measuring height |
150mm |
Minimum resolution |
0.001kg or 0.1g |
Minimum fine-tuning distance |
0.01mm |
X axis movement range |
0-75mm |
Y axis movement range |
0-75mm |
Transmission mechanism |
Ball screw drive |
Power supply |
AC220V |
Volume |
360*260*940mm |
Main test functions:
Kinetic resistance can be tested (ie: connector contact resistance measurement)
Can do connector single hole plug test
Can be used to connect the whole row plug test and connector plug life test
Can do connector single Pin and plastic retention test (ie: terminal retention test/fixed force point retention)
Can do connector NORMAL FORCE test
Can do general compression and tensile failure tests
Choice of continuous plug or single plug test
All point data on the waveform graph can be drawn and waveform graph remarks can be made
Can print and store graphics (plug displacement curve, life curve, inspection report, etc.)
Curve sampling rate can be set
Test data is stored in hard disk (each data can be stored, unlimited times)
The test conditions are all set in writing by the computer, which is convenient and fast (including plug-in stroke, speed, pause time... etc.)
The header content of the inspection report can be modified at any time
The inspection report can be transferred to Excel for editing