Light detection:
|
Add the rated voltage to the live wire and the neutral wire, and check whether the indicator light is on normally.
|
|||
Conduction Polarity Detection:
|
Detect the conduction and polarity between the head and tail of the charging gun
|
|||
Number of wire cores:
|
L1\L2\L3 can be set freely
|
|||
Heartbeat:
|
Voltage DC24V, about 10mA
|
|||
Polarity judgment:
|
Loop-type signal judgment can detect whether the sequence between all heads and tails is qualified;
|
|||
Alarm detection:
|
There are sound and light alarm prompts and text message prompts for wrong polarity and power failure;
|
|||
Insulation resistance parameters:
|
||||
Insulation voltage:
|
DC100~1000V can be set arbitrarily;
|
|||
Lower limit setting:
|
1M~1GΩ can be set arbitrarily;
|
|||
Accuracy:
|
±5%;
|
|||
Impedance indication:
|
The digital display meter head indicates the current insulation resistance value in real time;
|
|||
Alarm detection:
|
When the resistance value is less than the set value, there are sound and light alarm prompts and text prompts;
|
|||
Detection:
|
Conduct insulation test between L and N wires to PE and L and N wires to CC respectively.
|
|||
The test result must be greater than 500MΩ
|
||||
Voltage withstand test parameters:
|
||||
Withstanding voltage:
|
AC0~5kV/DC0~6kV can be set arbitrarily;
|
|||
Leakage Current Upper Limit:
|
AC0.1mA~20mA, DC0.01mA~5mA can be set arbitrarily
|
|||
Accuracy:
|
±1.5%+3 words
|
|||
Display method:
|
The digital display head indicates the current voltage
|
|||
Pressure regulation method:
|
Automatic program control
|
|||
Alarm detection:
|
When the leakage current value is greater than the set value, there are sound and light alarm prompts and text prompts;
|
|||
Detection:
|
The L and N wires are respectively connected to PE, and the L and N wires are respectively connected to CC to conduct withstand
voltage tests. |
|||
The test result must be less than 5mA
|
||||
Insulation test time:
|
1~999.9s
|
|||
Hipot test time:
|
1~999.9s
|
|||
Dimensions
|
W1000mmxD600m×H300mm
|
|||
weight:
|
About 100kg:
|
|||
power supply:
|
AC220V, 50Hz, about 10A
|