Scope of application:
Low frequency cyclic tensile testing machine controlled by microcomputer, this machine is mainly suitable for metal, non-metal and composite materials tensile and low frequency cyclic tensile and other mechanical properties test, can realize the combination of stress, strain, speed command control. It can automatically obtain the maximum test force value, yield strength, upper and lower yield point, tensile strength, cycle number and other parameters according to GB, JIS, ASTM, DIN and other standards, automatically generate the test report format, and can print the test report curve at any time.
According to the criteria:
1, according to GB/T2611-2007 "testing machine general technical conditions" and GB/T 16491-2008 "electronic universal testing machine" standard manufacturing;
2, according to GB/T12160-2002 "single-axis test for the extension meter" and GB/T16825-2008 "tensile testing machine inspection" verification and acceptance;
3, applicable to GB, JIS, ASTM, DIN and other standards.
Product parameter table:
Testing machine type |
HJ-6105 |
HJ-6205 |
HJ-6305 |
HJ-6405 |
HJ-6505 |
Maximum dynamic load (kN) |
±100 |
±200 |
±300 |
±400 |
±500 |
Test frequency (Hz) |
Low cycle fatigue 0.01~20, high cycle fatigue 0.01~50, customized 0.01~100 |
Actuator stroke (mm) |
±50, ±75, ±100, ±150 and customized |
Test load waveform |
Sine wave, triangle wave, square wave, oblique wave, trapezoid wave, combination of custom waveform |
Measurement accuracy |
load |
Better than the indicated value ±1%, ±0.5% (static); Better than indicated value ±2% (dynamic) |
deformation |
Better than the indicated value ±1%, ±0.5% (static); Better than indicated value ±2% (dynamic) |
displacement |
Better than the indicated value ±1%, ±0.5% |
Test parameter measurement range |
1~100%FS (full scale), can be extended to 0.4 ~100%FS |
2~100%FS (full scale) |
Test space (mm) |
50~580 |
50~580 |
Test width (mm) |
500 |
600 |
Oil source configuration (21Mpa motor power) |
20L/min (7.50kW), 40L/min (15.0kW), 60L/min (22.0kW),00L/nin (37.0kw) discharge oil sources work in combination according to requirements, with optional pressure of 14, 21, 25mpa |