Product Description
Scope of application:
Steady state acceleration centrifugal testing machine for determining electronic components, small equipment and other electrical and electronic products under the action of forces (except gravity) generated by dynamic overload environment. The structure of the response and performance is good, as well as to assess the structural integrity of some components, and verify that these components in the expected use of the environment under the composite acceleration stress is normal and the bearing capacity of the structure.
Test principle:
simulate dynamic centrifugal movement, dual environmental force centrifugal movement and center high-speed rotating movement and other ways of a test means to assess the anti-load performance of electronic components, small components and other electrical and electronic products and test the anti-load performance indicators of the test equipment. It is mainly used for routine dynamic structural integrity and adaptability test of components, small parts and small machine on aircraft.
Equipment features:
1. High acceleration rate;
2. Computer centralized control and measurement;
3. Full digital network closed-loop remote control, high control accuracy;
4 Complete security protection functions.
Product parameters:
Model number |
HJ-1 |
HJ-2 |
HJ-3 |
HJ-4 |
HJ-5 |
parameter |
Double ambient centrifugal constant acceleration tester |
High speed spin testing machine |
Centrifugal dynamic overload testing machine |
Spin impact composite testing machine |
Centrifugal vibration composite testing machine |
Simplex load (KG) |
5 |
5 |
50 |
3 |
1000 |
Maximum acceleration (G) |
150 |
/ |
20 |
Impact 10000G-IMS |
50G |
Loading rate (G/S) |
Customized according to user requirements |
/ |
10 |
/ |
Standard electromagnetic shaking table specifications |
Mounting radius (MM) |
Customized according to user requirements |
/ |
1500 |
/ |
Customized according to user requirements |
Spin speed (R/MIN) |
0-3000 |
0-100000 |
/ |
0-10000 |
/ |
Collecting ring device |
Optional according to user requirements |
Control mode |
Full closed loop digital network (remote) automatic control + manual control |
Power supply |
AC 380V ± 10% 50HZ |
Working environment |
Temperature 0 ~ 40ºC humidity < 80% (no condensation) |
Meet the criteria |
GB/T 2423. GJB 150A, GJB1027,GJB360B |